Yang, Jian, Liu, Shoubao, Fang, Yuan, Xiong, Zhonghao, Li, Xin.
2020.
A simulation calculation method for suppressing the magnetizing inrush current in the setting of the overcurrent protection of the connecting transformer in the hydropower station. 2020 5th International Conference on Mechanical, Control and Computer Engineering (ICMCCE). :197–202.
In order to improve the reliability of power supply in adjacent hydropower stations, the auxiliary power systems of the two stations are connected through a contact transformer. The magnetizing inrush current generated by the connecting transformer of a hydropower station has the characteristics of high frequency, strong energy, and multi-coupling. The harm caused by the connecting transformer is huge. In order to prevent misoperation during the closing process of the connecting transformer, this article aims at the problem of setting the switching current of the connecting transformer of the two hydropower stations, and establishes the analysis model of the excitation inrush current with SimPowerSystem software, and carries out the quantitative simulation calculation of the excitation inrush current of the connecting transformer. A setting strategy for overcurrent protection of tie transformers to suppress the excitation inrush current is proposed. Under the conditions of changing switch closing time, generator load, auxiliary transformer load, tie transformer core remanence, the maximum amplitude of the excitation inrush current is comprehensively judged Value, and then achieve the suppression of the excitation inrush current, and accurately determine the protection setting of the switch.
Loreto, Jayson, Gerasta, Olga Joy L., Gumera, Aileen C..
2020.
Residual Current Circuit Implemented in Complementary Metal Oxide Semiconductor for Remanence Correction. 2020 IEEE 12th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management (HNICEM). :1–6.
This research paper presented a design that will address the challenges brought by remanence in ground-fault current interrupter devices (gfci). Remanence or residual magnetism is the magnetization left behind in a ferromagnetic material (such as iron) after an external magnetic field is removed. Remanence will make the gfci devices less accurate and less reliable in tripping the current above threshold in just five (5) years. It affects the performance of the device in terms of efficiency, accuracy, and response time. In this research, the problems caused by remanence were alleviated by using two identical transformers in detecting residual current both for hot and neutral wires. The difference of the current detected by the two transformers will be the basis of the signal threshold in tripping the device. By doing so, the problems caused by remanence phenomenon will be solved without compromising the response time of the circuit which is around 16 mS. The design will extend the life span of GFCI devices up to 15 years.