Visible to the public Biblio

Filters: Keyword is automatic generation control  [Clear All Filters]
2022-09-20
Yan, Weili, Lou, Xin, Yau, David K.Y., Yang, Ying, Saifuddin, Muhammad Ramadan, Wu, Jiyan, Winslett, Marianne.  2021.  A Stealthier False Data Injection Attack against the Power Grid. 2021 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm). :108—114.
We use discrete-time adaptive control theory to design a novel false data injection (FDI) attack against automatic generation control (AGC), a critical system that maintains a power grid at its requisite frequency. FDI attacks can cause equipment damage or blackouts by falsifying measurements in the streaming sensor data used to monitor the grid's operation. Compared to prior work, the proposed attack (i) requires less knowledge on the part of the attacker, such as correctly forecasting the future demand for power; (ii) is stealthier in its ability to bypass standard methods for detecting bad sensor data and to keep the false sensor readings near historical norms until the attack is well underway; and (iii) can sustain the frequency excursion as long as needed to cause real-world damage, in spite of AGC countermeasures. We validate the performance of the proposed attack on realistic 37-bus and 118-bus setups in PowerWorld, an industry-strength power system simulator trusted by real-world operators. The results demonstrate the attack's improved stealthiness and effectiveness compared to prior work.
2021-05-13
Chen, Ziyu, Zhu, Jizhong, Li, Shenglin, Luo, Tengyan.  2020.  Detection of False Data Injection Attack in Automatic Generation Control System with Wind Energy based on Fuzzy Support Vector Machine. IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society. :3523—3528.
False data injection attack (FDIA) destroys the automatic generation control (AGC) system and leads to unstable operation of the power system. Fast and accurate detection can help prevent and disrupt malicious attacks. This paper proposes an improved detection method, which is combined with fuzzy theory and support vector machine (SVM) to identify various types of attacks. The impacts of different types of FDIAs on the AGC system are analyzed, and the reliability of the method is proved by a large number of experimental data. This experiment is simulated on a single-area LFC system and the effects of adding a wind storage system were compared in a dynamic model. Simulation studies also show a higher accuracy of fuzzy support vector machine (FSVM) than traditional SVM and fuzzy pattern trees (FPTs).
2021-02-16
Siu, J. Y., Panda, S. Kumar.  2020.  A Specification-Based Detection for Attacks in the Multi-Area System. IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society. :1526—1526.
In the past decade, cyber-attack events on the power grid have proven to be sophisticated and advanced. These attacks led to severe consequences on the grid operation, such as equipment damage or power outages. Hence, it is more critical than ever to develop tools for security assessment and detection of anomalies in the cyber-physical grid. For an extensive power grid, it is complex to analyze the causes of frequency deviations. Besides, if the system is compromised, attackers can leverage on the frequency deviation to bypass existing protection measures of the grid. This paper aims to develop a novel specification-based method to detect False Data Injection Attacks (FDIAs) in the multi-area system. Firstly, we describe the implementation of a three-area system model. Next, we assess the risk and devise several intrusion scenarios. Specifically, we inject false data into the frequency measurement and Automatic Generation Control (AGC) signals. We then develop a rule-based method to detect anomalies at the system-level. Our simulation results proves that the proposed algorithm can detect FDIAs in the system.
2020-07-16
Ding, Yueming, Li, Kuan, Meng, Zhaoxian.  2018.  CPS Optimal Control for Interconnected Power Grid Based on Model Predictive Control. 2018 2nd IEEE Conference on Energy Internet and Energy System Integration (EI2). :1—9.

The CPS standard can be more objective to evaluate the effect of control behavior in each control area on the interconnected power grid. The CPS standard is derived from statistical methods emphasizing the long-term control performance of AGC, which is beneficial to the frequency control of the power grid by mutual support between the various power grids in the case of an accident. Moreover, CPS standard reduces the wear of the equipment caused by the frequent adjustment of the AGC unit. The key is to adjust the AGC control strategy to meet the performance of CPS standard. This paper proposed a dynamic optimal CPS control methodology for interconnected power systems based on model predictive control which can achieve optimal control under the premise of meeting the CPS standard. The effectiveness of the control strategy is verified by simulation examples.

2018-02-02
Ashok, A., Sridhar, S., McKinnon, A. D., Wang, P., Govindarasu, M..  2016.  Testbed-based performance evaluation of Attack Resilient Control for AGC. 2016 Resilience Week (RWS). :125–129.

The modern electric power grid is a complex cyber-physical system whose reliable operation is enabled by a wide-area monitoring and control infrastructure. Recent events have shown that vulnerabilities in this infrastructure may be exploited to manipulate the data being exchanged. Such a scenario could cause the associated control applications to mis-operate, potentially causing system-wide instabilities. There is a growing emphasis on looking beyond traditional cybersecurity solutions to mitigate such threats. In this paper we perform a testbed-based validation of one such solution - Attack Resilient Control (ARC) - on Iowa State University's PowerCyber testbed. ARC is a cyber-physical security solution that combines domain-specific anomaly detection and model-based mitigation to detect stealthy attacks on Automatic Generation Control (AGC). In this paper, we first describe the implementation architecture of the experiment on the testbed. Next, we demonstrate the capability of stealthy attack templates to cause forced under-frequency load shedding in a 3-area test system. We then validate the performance of ARC by measuring its ability to detect and mitigate these attacks. Our results reveal that ARC is efficient in detecting stealthy attacks and enables AGC to maintain system operating frequency close to its nominal value during an attack. Our studies also highlight the importance of testbed-based experimentation for evaluating the performance of cyber-physical security and control applications.

2017-11-27
Biswas, S., Sarwat, A..  2016.  Vulnerabilities in two-area Automatic Generation Control systems under cyberattack. 2016 Resilience Week (RWS). :40–45.

The power grid is a prime target of cyber criminals and warrants special attention as it forms the backbone of major infrastructures that drive the nation's defense and economy. Developing security measures for the power grid is challenging since it is physically dispersed and interacts dynamically with associated cyber infrastructures that control its operation. This paper presents a mathematical framework to investigate stability of two area systems due to data attacks on Automatic Generation Control (AGC) system. Analytical and simulation results are presented to identify attack levels that could drive the AGC system to potentially become unstable.

2015-05-05
Popli, N., Ilic, M.D..  2014.  Storage devices for automated frequency regulation and stabilization. PES General Meeting | Conference Exposition, 2014 IEEE. :1-5.

In this paper we propose a framework for automating feedback control to balance hard-to-predict wind power variations. The power imbalance is a result of non-zero mean error around the wind power forecast. Our proposed framework is aimed at achieving the objective of frequency stabilization and regulation through one control action. A case-study for a real-world system on Flores island in Portugal is provided. Using a battery-based storage on the island, we illustrate the proposed control framework.
 

2015-04-30
Sridhar, S., Govindarasu, M..  2014.  Model-Based Attack Detection and Mitigation for Automatic Generation Control. Smart Grid, IEEE Transactions on. 5:580-591.

Cyber systems play a critical role in improving the efficiency and reliability of power system operation and ensuring the system remains within safe operating margins. An adversary can inflict severe damage to the underlying physical system by compromising the control and monitoring applications facilitated by the cyber layer. Protection of critical assets from electronic threats has traditionally been done through conventional cyber security measures that involve host-based and network-based security technologies. However, it has been recognized that highly skilled attacks can bypass these security mechanisms to disrupt the smooth operation of control systems. There is a growing need for cyber-attack-resilient control techniques that look beyond traditional cyber defense mechanisms to detect highly skilled attacks. In this paper, we make the following contributions. We first demonstrate the impact of data integrity attacks on Automatic Generation Control (AGC) on power system frequency and electricity market operation. We propose a general framework to the application of attack resilient control to power systems as a composition of smart attack detection and mitigation. Finally, we develop a model-based anomaly detection and attack mitigation algorithm for AGC. We evaluate the detection capability of the proposed anomaly detection algorithm through simulation studies. Our results show that the algorithm is capable of detecting scaling and ramp attacks with low false positive and negative rates. The proposed model-based mitigation algorithm is also efficient in maintaining system frequency within acceptable limits during the attack period.