Visible to the public Biblio

Filters: Keyword is cold tuner  [Clear All Filters]
2018-05-16
Ciovati, G., Cheng, G., Drury, M., Fischer, J., Geng, R..  2017.  Impact of Remanent Magnetic Field on the Heat Load of Original CEBAF Cryomodule. IEEE Transactions on Applied Superconductivity. 27:1–6.

The heat load of the original cryomodules for the continuous electron beam accelerator facility is 50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being 50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank, and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.