Visible to the public Biblio

Filters: Keyword is Permittivity  [Clear All Filters]
2021-01-20
Sato, Y., Yanagitani, T..  2020.  Giga-hertz piezoelectric epitaxial PZT transducer for the application of fingerprint imaging. 2020 IEEE International Ultrasonics Symposium (IUS). :1—3.

The fingerprint sensor based on pMUTs was reported [1]. Spatial resolution of the image depends on the size of the acoustic source when a plane wave is used. If the size of the acoustic source is smaller, piezoelectric films with high dielectric constant are required. In this study, in order to obtain small acoustic source, we proposed Pb(Zrx Th-x)O3 (PZT) epitaxial transducers with high dielectric constant. PbTiO3 (PTO) epitaxial films were grown on conductive La-SrTiO3 (STO) substrate by RF magnetron sputtering. Longitudinal wave conversion loss of PTO transducers was measured by a network analyzer. The thermoplastic elastomer was used instead of real fingerprint. We confirmed that conversion loss of piezoelectric film/substrate structure was increased by contacting the elastomer due the change of reflection coefficient of the substrate bottom/elastomer interface. Minimum conversion loss images were obtained by mechanically scanning the soft probe on the transducer surface. We achieved the detection of the fingerprint phantom based on the elastomer in the GHz.

2020-11-30
Wang, Y., Huang, F., Hu, Y., Cao, R., Shi, T., Liu, Q., Bi, L., Liu, M..  2018.  Proton Radiation Effects on Y-Doped HfO2-Based Ferroelectric Memory. IEEE Electron Device Letters. 39:823–826.
In this letter, ferroelectric memory performance of TiN/Y-doped-HfO2 (HYO)/TiN capacitors is investigated under proton radiation with 3-MeV energy and different fluence (5e13, 1e14, 5e14, and 1e15 ions/cm2). X-ray diffraction patterns confirm that the orthorhombic phase Pbc21 of HYOfilm has no obvious change after proton radiation. Electrical characterization results demonstrate slight variations of the permittivity and ferroelectric hysteresis loop after proton radiation. The remanent polarization (2Pr) of the capacitor decreases with increasing proton fluence. But the decreasing trend of 2Pr is suppressed under high electric fields. Furthermore, the 2Pr degradation with cycling is abated by proton radiation. These results show that the HYO-based ferroelectric memory is highly resistive to proton radiation, which is potentially useful for space applications.
2020-04-24
de Almeida Arantes, Daniel, Borges da Silva, Luiz Eduardo, Teixeira, Carlos Eduardo, Campos, Mateus Mendes, Lambert-Torres, Germano, Bonaldi, Erik Leandro, de Lacerda de Oliveira, Levy Ely, da Costa, Germando Araújo.  2019.  Relative Permittivity Meter Using a Capacitive Sensor and an Oscillating Current Source. IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society. 1:806—811.

The relative permittivity (also known as dielectric constant) is one of the physical properties that characterize a substance. The measurement of its magnitude can be useful in the analysis of several fluids, playing an important role in many industrial processes. This paper presents a method for measuring the relative permittivity of fluids, with the possibility of real-time monitoring. The method comprises the immersion of a capacitive sensor inside a tank or duct, in order to have the inspected substance as its dielectric. An electronic circuit is responsible for exciting this sensor, which will have its capacitance measured through a quick analysis of two analog signals outputted by the circuit. The developed capacitance meter presents a novel topology derived from the well-known Howland current source. One of its main advantages is the capacitance-selective behavior, which allows the system to overcome the effects of parasitic resistive and inductive elements on its readings. In addition to an adjustable current output that suits different impedance magnitudes, it exhibits a steady oscillating behavior, thus allowing continuous operation without any form of external control. This paper presents experimental results obtained from the proposed system and compares them to measurements made with proven and calibrated equipment. Two initial capacitance measurements performed with the system for evaluating the sensor's characteristics exhibited relative errors of approximately 0.07% and 0.53% in comparison to an accurate workbench LCR meter.