Biblio
Filters: Keyword is Protective relaying [Clear All Filters]
Optimal Solution Discrimination of an Analytic Model for Power Grid Fault Diagnosis Employing Electrical Criterion. 2021 4th International Conference on Energy, Electrical and Power Engineering (CEEPE). :744–750.
.
2021. When a fault occurs in power grid, the analytic model for power grid fault diagnosis could generate multiple solutions under one or more protective relays (PRs) and/or circuit breakers (CBs) malfunctioning, and/or one or more their alarm information failing. Hence, this paper, calling the electrical quantities, presents an optimal solution discrimination method, which determines the optimal solution by constructing the electrical criteria of suspicious faulty components. Furthermore, combining the established electrical criteria with the existing analytic model, a hierarchical fault diagnosis mode is proposed. It uses the analytic model for the first level diagnosis based on the switching quantities. Thereafter, aiming at multiple solutions, it applies the electrical criteria for the second level diagnosis to determine the diagnostic result. Finally, the examples of fault diagnosis demonstrate the feasibility and effectiveness of the developed method.
Factors influencing CT saturation and its implications on Distance Protection Scheme-Analysis and Testing. 2021 74th Conference for Protective Relay Engineers (CPRE). :1–11.
.
2021. The behavior of the Current Transformer (CTs) is of utmost importance for protection engineers to ensure reliable operation of power system. CT magnetic saturation is a well-known phenomenon when analyzing its performance characteristics. Nevertheless, transient conditions in the system might be different every time. A good understanding of the magnetic saturation of different CT designs and the effect of saturation on the protection schemes is imperative for developing a robust and dependable protection system. In this paper, various factors that affect CT saturation like X/R ratio, large current magnitudes, DC offset, burden and magnetization remanence are discussed. Analysis of CT saturation based on changes to burden and remanence is performed. In addition to that, the effect of saturation due to these factors on distance protection are presented with test results and analysis. Saturation conditions are analyzed on mho distance elements during phase to ground and three phase faults. Finally, a practical approach to efficiently test the performance of protection schemes under CT saturation conditions is proposed using COMTRADE play back. COMTRADE play back files for various scenarios of CT saturation conditions are generated and used for testing the performance of the protection scheme.
A Collaborative Defense for Securing Protective Relay Settings in Electrical Cyber Physical Systems. 2018 Resilience Week (RWS). :49—54.
.
2018. Modern power systems today are protected and controlled increasingly by embedded systems of computing technologies with a great degree of collaboration enabled by communication. Energy cyber-physical systems such as power systems infrastructures are increasingly vulnerable to cyber-attacks on the protection and control layer. We present a method of securing protective relays from malicious change in protective relay settings via collaboration of devices. Each device checks the proposed setting changes of its neighboring devices for consistency and coordination with its own settings using setting rules based on relay coordination principles. The method is enabled via peer-to-peer communication between IEDs. It is validated in a cyber-physical test bed containing a real time digital simulator and actual relays that communicate via IEC 61850 GOOSE messages. Test results showed improvement in cyber physical security by using domain based rules to block malicious changes in protection settings caused by simulated cyber-attacks. The method promotes the use of defense systems that are aware of the physical systems which they are designed to secure.
A Creditability-based Intrusion Tolerant Method for Protection Equipment in Transformer Substations. 2018 China International Conference on Electricity Distribution (CICED). :1489–1492.
.
2018. With the development of the interconnection of all things(IoT), a large number of mobile terminal devices with multiple users access the distribution network, and gradually form an open and interconnected network environment, which brings new challenges to the security and protection of the distribution network. In this paper, a method of analyzing the sensing data of the digital substation is proposed, which can prevent the abnormal data from causing the malfunction of the protective relays by calculating the creditability of the sensing data. Creditability calculation algorithm as well as the implementation of the intrusion tolerance strategy are studied throughout the paper. The simulation results show that the proposed creditability-based intrusion-tolerant(CIT) algorithm can ensure that the protective equipment have no protective malfunction from the false instructions or false data attacks, and the proposed intrusion tolerant algorithm has little affect on the real-time performance of the original protection algorithm, hence it has some practical value.