Visible to the public Biblio

Filters: Keyword is partial discharges  [Clear All Filters]
2021-01-25
Merouane, E. M., Escudero, C., Sicard, F., Zamai, E..  2020.  Aging Attacks against Electro-Mechanical Actuators from Control Signal Manipulation. 2020 IEEE International Conference on Industrial Technology (ICIT). :133–138.
The progress made in terms of controller technologies with the introduction of remotely-accessibility capacity in the digital controllers has opened the door to new cybersecurity threats on the Industrial Control Systems (ICSs). Among them, some aim at damaging the ICS's physical system. In this paper, a corrupted controller emitting a non-legitimate Pulse Width Modulation control signal to an Electro-Mechanical Actuator (EMA) is considered. The attacker's capabilities for accelerating the EMA's aging by inducing Partial Discharges (PDs) are investigated. A simplified model is considered for highlighting the influence of the carrier frequency of the control signal over the amplitude and the repetition of the PDs involved in the EMA's aging.
2020-08-03
Si, Wen-Rong, Huang, Xing-De, Xin, Zi, Lu, Bing-Bing, Bao, Hai-Long, Xu, Peng, Li, Jun-Hao.  2019.  Research on a General Fast Analysis Algorithm Model for PD Acoustic Detection System: Pattern Identification with Phase Compensation. 2019 11th International Conference on Measuring Technology and Mechatronics Automation (ICMTMA). :288–292.
At present, the acoustic emission (AE) method has the advantages of live measurement and easy fault location, so it is very suitable for insulation defect detection of power equipments such as GIS, etc. While the conventional AE detection system or instruments always can't give a right discrimination result, because them always work based on the reference voltage or phase information from an auxiliary 220V voltage signal source rather than the operation high voltage (HV) with the real phase information corresponding to the detected AE pulsed signals. So there is a random phase difference between the reference phase and operation phase. The discharge fingerprint formed by the detected AE pulsed signals with reference phase using the same processing process is compared to the discharge fingerprint database formed in the HV laboratory with the real phase information, therefore, the system may not be able to discriminate the discharge mode of the field measured data from GIS in substation operation. In this paper, in order to design and develop a general fast analysis algorithm model for PD acoustic detection system to make an assistant diagnosis, the pattern identification with phase compensation was designed and applied. The results show that the method is effective and useful to deatl with AE signals meased in operation situation.