Biblio
Cyber-attacks in electrical power system causes serious damages causing breakdown of few equipment to shutdown of the complete power system. Game theory is used as a tool to detect the cyber-attack in the power system recently. Interaction between the attackers and the defenders which is the inherent nature of the game theory is exploited to detect the cyber-attack in the power system. This paper implements the cyber-attack detection on a two-area power system controlled using the Load Frequency controller. Ant Lion Optimization is used to tune the integral controller applied in the Load Frequency Controller. Cyber-attacks that include constant injection, bias injection, overcompensation, and negative compensation are tested on the Game theory-based attack detection algorithm proposed. It is considered that the smart meters are attacked with the attacks by manipulating the original data in the power system. MATLAB based implementation is developed and observed that the defender action is satisfactory in the two-area system considered. Tuning of integral controller in the Load Frequency controller in the two-area system is also observed to be effective.