2020-05-22
Jaiswal, Supriya, Ballal, Makarand Sudhakar.  2019.  A Novel Online Technique for Fixing the Accountability of Harmonic Injector in Distribution Network. 2019 Innovations in Power and Advanced Computing Technologies (i-PACT). 1:1—7.

Harmonic distortions come into existence in the power system not only due to nonlinear loads of consumers but also due to custom power devices used by power utilities. These distortions are harmful to the power networks as these produce over heating of appliances, reduction in their life expectancy, increment in electricity bill, false tripping, etc. This paper presents an effective, simple and direct approach to identify the problematic cause either consumer load or utility source or both responsible for harmonics injection in the power system. This technique does not require mathematical model, historical data and expert knowledge. The online methodology is developed in the laboratory and tested for different polluted loads and source conditions. Experimental results are found satisfactory. This proposed technique has substantial potential to determine the problematic cause without any power interruption by plug and play operation just like CCTV.

2020-01-20
Ohata, Keita, Adachi, Masakazu, Kusaka, Keisuke, Itoh, Jun-Ichi.  2019.  Three-phase AC-DC Converter for EV Rapid Charging with Wireless Communication for Decentralized Controller. 2019 10th International Conference on Power Electronics and ECCE Asia (ICPE 2019 - ECCE Asia). :3033–3039.

This paper proposes a multi-modular AC-DC converter system using wireless communication for a rapid charger of electric vehicles (EVs). The multi-modular topology, which consists of multiple modules, has an advantage on the expandability regarding voltage and power. In the proposed system, the input current and output voltage are controlled by each decentralized controller, which wirelessly communicates to the main controller, on each module. Thus, high-speed communication between the main and modules is not required. As the results in a reduced number of signal lines. The fundamental effectiveness of the proposed system is verified with a 3-kW prototype. In the experimented results, the input current imbalance rate is reduced from 49.4% to 0.1%, where total harmonic distortion is less than 3%.

2015-05-06
Nikolic, G., Nikolic, T., Petrovic, B..  2014.  Using adaptive filtering in single-phase grid-connected system. Microelectronics Proceedings - MIEL 2014, 2014 29th International Conference on. :417-420.

Recently, there has been a pronounced increase of interest in the field of renewable energy. In this area power inverters are crucial building blocks in a segment of energy converters, since they change direct current (DC) to alternating current (AC). Grid connected power inverters should operate in synchronism with the grid voltage. In this paper, the structure of a power system based on adaptive filtering is described. The main purpose of the adaptive filter is to adapt the output signal of the inverter to the corresponding load and/or grid signal. By involving adaptive filtering the response time decreases and quality of power delivery to the load or grid increases. A comparative analysis which relates to power system operation without and with adaptive filtering is given. In addition, the impact of variable impedance of load on quality of delivered power is considered. Results which relates to total harmonic distortion (THD) factor are obtained by Matlab/Simulink software.