The NEREIDA wave generation power plant installed in Mutriku, Spain is a multiple Oscillating Water Column (OWC) plant. The power takeoff consists of a Wells turbine coupled to a Doubly Fed Induction Generator (DFIG). The stalling behavior present in the Wells turbine limits the generated power. This paper presents the modeling and a Harmony Search Algorithm-based airflow control of the OWC. The Harmony Search Algorithm (HSA) is proposed to help overcome the limitations of a traditionally tuned PID. An investigation between HSA-tuned controller and the traditionally tuned controller has been performed. Results of the controlled and uncontrolled plant prove the effectiveness of the airflow control and the superiority of the HSA-tuned controller.
This paper deals with the modeling and control of the NEREIDA wave generation power plant installed in Mutriku, Spain. This kind of Oscillating Water Column (OWC) plants usually employ a Wells turbine coupled to a Doubly Fed Induction Generator (DFIG). The stalling behavior of the Wells turbine limits the generated power. In this context, a sliding mode rotational speed control is proposed to help avoiding this phenomenon. This will regulate the speed by means of the Rotor Side Converter (RSC) of the Back-to-Back converter governing the generator. The results of the comparative study show that the proposed control provides a higher generated power compared to the uncontrolled case.