Visible to the public Biblio

Filters: Keyword is Valves  [Clear All Filters]
2022-12-23
Faramondi, Luca, Grassi, Marta, Guarino, Simone, Setola, Roberto, Alcaraz, Cristina.  2022.  Configuration vulnerability in SNORT for Windows Operating Systems. 2022 IEEE International Conference on Cyber Security and Resilience (CSR). :82–89.
Cyber-attacks against Industrial Control Systems (ICS) can lead to catastrophic events which can be prevented by the use of security measures such as the Intrusion Prevention Systems (IPS). In this work we experimentally demonstrate how to exploit the configuration vulnerabilities of SNORT one of the most adopted IPSs to significantly degrade the effectiveness of the IPS and consequently allowing successful cyber-attacks. We illustrate how to design a batch script able to retrieve and modify the configuration files of SNORT in order to disable its ability to detect and block Denial of Service (DoS) and ARP poisoning-based Man-In-The-Middle (MITM) attacks against a Programmable Logic Controller (PLC) in an ICS network. Experimental tests performed on a water distribution testbed show that, despite the presence of IPS, the DoS and ARP spoofed packets reach the destination causing respectively the disconnection of the PLC from the ICS network and the modification of packets payload.
2021-09-30
Wang, Guoqing, Zhuang, Lei, Liu, Taotao, Li, Shuxia, Yang, Sijin, Lan, Julong.  2020.  Formal Analysis and Verification of Industrial Control System Security via Timed Automata. 2020 International Conference on Internet of Things and Intelligent Applications (ITIA). :1–5.
The industrial Internet of Things (IIoT) can facilitate industrial upgrading, intelligent manufacturing, and lean production. Industrial control system (ICS) is a vital support mechanism for many key infrastructures in the IIoT. However, natural defects in the ICS network security mechanism and the susceptibility of the programmable logic controller (PLC) program to malicious attack pose a threat to the safety of national infrastructure equipment. To improve the security of the underlying equipment in ICS, a model checking method based on timed automata is proposed in this work, which can effectively model the control process and accurately simulate the system state when incorporating time factors. Formal analysis of the ICS and PLC is then conducted to formulate malware detection rules which can constrain the normal behavior of the system. The model checking tool UPPAAL is then used to verify the properties by detecting whether there is an exception in the system and determine the behavior of malware through counter-examples. The chemical reaction control system in Tennessee-Eastman process is taken as an example to carry out modeling, characterization, and verification, and can effectively detect multiple patterns of malware and propose relevant security policy recommendations.
2020-11-02
Shayan, Mohammed, Bhattacharjee, Sukanta, Song, Yong-Ak, Chakrabarty, Krishnendu, Karri, Ramesh.  2019.  Deceive the Attacker: Thwarting IP Theft in Sieve-Valve-based Biochips. 2019 Design, Automation Test in Europe Conference Exhibition (DATE). :210—215.

Researchers develop bioassays following rigorous experimentation in the lab that involves considerable fiscal and highly-skilled-person-hour investment. Previous work shows that a bioassay implementation can be reverse engineered by using images or video and control signals of the biochip. Hence, techniques must be devised to protect the intellectual property (IP) rights of the bioassay developer. This study is the first step in this direction and it makes the following contributions: (1) it introduces use of a sieve-valve as a security primitive to obfuscate bioassay implementations; (2) it shows how sieve-valves can be used to obscure biochip building blocks such as multiplexers and mixers; (3) it presents design rules and security metrics to design and measure obfuscated biochips. We assess the cost-security trade-offs associated with this solution and demonstrate practical sieve-valve based obfuscation on real-life biochips.

2020-07-30
Shayan, Mohammed, Bhattacharjee, Sukanta, Song, Yong-Ak, Chakrabarty, Krishnendu, Karri, Ramesh.  2019.  Can Multi-Layer Microfluidic Design Methods Aid Bio-Intellectual Property Protection? 2019 IEEE 25th International Symposium on On-Line Testing and Robust System Design (IOLTS). :151—154.
Researchers develop bioassays by rigorously experimenting in the lab. This involves significant fiscal and skilled person-hour investment. A competitor can reverse engineer a bioassay implementation by imaging or taking a video of a biochip when in use. Thus, there is a need to protect the intellectual property (IP) rights of the bioassay developer. We introduce a novel 3D multilayer-based obfuscation to protect a biochip against reverse engineering.
2020-04-24
Serras, Paula, Ibarra-Berastegi, Gabriel, Saénz, Jon, Ulazia, Alain, Esnaola, Ganix.  2019.  Analysis of Wells-type turbines’ operational parameters during winter of 2014 at Mutriku wave farm. OCEANS 2019 – Marseille. :1—5.

Mutriku wave farm is the first commercial plant all around the world. Since July 2011 it has been continuously selling electricity to the grid. It operates with the OWC technology and has 14 operating Wells-type turbines. In the plant there is a SCADA data recording system that collects the most important parameters of the turbines; among them, the pressure in the inlet chamber, the position of the security valve (from fully open to fully closed) and the generated power in the last 5 minutes. There is also an electricity meter which provides information about the amount of electric energy sold to the grid. The 2014 winter (January, February and March), and especially the first fortnight of February, was a stormy winter with rough sea state conditions. This was reflected both in the performance of the turbines (high pressure values, up to 9234.2 Pa; low opening degrees of the security valve, down to 49.4°; and high power generation of about 7681.6 W, all these data being average values) and in the calculated capacity factor (CF = 0.265 in winter and CF = 0.294 in February 2014). This capacity factor is a good tool for the comparison of different WEC technologies or different locations and shows an important seasonal behavior.

2020-03-12
Salmani, Hassan, Hoque, Tamzidul, Bhunia, Swarup, Yasin, Muhammad, Rajendran, Jeyavijayan JV, Karimi, Naghmeh.  2019.  Special Session: Countering IP Security Threats in Supply Chain. 2019 IEEE 37th VLSI Test Symposium (VTS). :1–9.

The continuing decrease in feature size of integrated circuits, and the increase of the complexity and cost of design and fabrication has led to outsourcing the design and fabrication of integrated circuits to third parties across the globe, and in turn has introduced several security vulnerabilities. The adversaries in the supply chain can pirate integrated circuits, overproduce these circuits, perform reverse engineering, and/or insert hardware Trojans in these circuits. Developing countermeasures against such security threats is highly crucial. Accordingly, this paper first develops a learning-based trust verification framework to detect hardware Trojans. To tackle Trojan insertion, IP piracy and overproduction, logic locking schemes and in particular stripped functionality logic locking is discussed and its resiliency against the state-of-the-art attacks is investigated.

2018-03-05
Sugumar, G., Mathur, A..  2017.  Testing the Effectiveness of Attack Detection Mechanisms in Industrial Control Systems. 2017 IEEE International Conference on Software Quality, Reliability and Security Companion (QRS-C). :138–145.

Industrial Control Systems (ICS) are found in critical infrastructure such as for power generation and water treatment. When security requirements are incorporated into an ICS, one needs to test the additional code and devices added do improve the prevention and detection of cyber attacks. Conducting such tests in legacy systems is a challenge due to the high availability requirement. An approach using Timed Automata (TA) is proposed to overcome this challenge. This approach enables assessment of the effectiveness of an attack detection method based on process invariants. The approach has been demonstrated in a case study on one stage of a 6- stage operational water treatment plant. The model constructed captured the interactions among components in the selected stage. In addition, a set of attacks, attack detection mechanisms, and security specifications were also modeled using TA. These TA models were conjoined into a network and implemented in UPPAAL. The models so implemented were found effective in detecting the attacks considered. The study suggests the use of TA as an effective tool to model an ICS and study its attack detection mechanisms as a complement to doing so in a real plant-operational or under design.

2018-02-15
Wang, X., Lin, S., Wang, S., Shi, J., Zhang, C..  2017.  A multi-fault diagnosis strategy of electro-hydraulic servo actuation system based on extended Kalman filter. 2017 IEEE International Conference on Cybernetics and Intelligent Systems (CIS) and IEEE Conference on Robotics, Automation and Mechatronics (RAM). :614–619.

Electro-hydraulic servo actuation system is a mechanical, electrical and hydraulic mixing complex system. If it can't be repaired for a long time, it is necessary to consider the possibility of occurrence of multiple faults. Considering this possibility, this paper presents an extended Kalman filter (EKF) based method for multiple faults diagnosis. Through analysing the failure modes and mechanism of the electro-hydraulic servo actuation system and modelling selected typical failure modes, the relationship between the key parameters of the system and the faults is obtained. The extended Kalman filter which is a commonly used algorithm for estimating parameters is used to on-line fault diagnosis. Then use the extended Kalman filter to diagnose potential faults. The simulation results show that the multi-fault diagnosis method based on extended Kalman filter is effective for multi-fault diagnosis of electro-hydraulic servo actuation system.

Mhamdi, L., Njima, C. B., Dhouibi, H., Hassani, M..  2017.  Using timed automata and fuzzy logic for diagnosis of multiple faults in DES. 2017 International Conference on Control, Automation and Diagnosis (ICCAD). :457–463.

This paper proposes a design method of a support tool for detection and diagnosis of failures in discrete event systems (DES). The design of this diagnoser goes through three phases: an identification phase and finding paths and temporal parameters of the model describing the two modes of normal and faulty operation, a detection phase provided by the comparison and monitoring time operation and a location phase based on the combination of the temporal evolution of the parameters and thresholds exceeded technique. Our contribution lays in the application of this technique in the presence of faults arising simultaneously, sensors and actuators. The validation of the proposed approach is illustrated in a filling system through a simulation.