Biblio
Conventional photoacoustic microscopy (PAM) involves detection of optically induced thermo-elastic waves using ultrasound transducers. This approach requires acoustic coupling and the spatial resolution is limited by the focusing properties of the transducer. We present an all-optical PAM approach that involved detection of the photoacoustically induced surface displacements using an adaptive, two-wave mixing interferometer. The interferometer consisted of a 532-nm, CW laser and a Bismuth Silicon Oxide photorefractive crystal (PRC) that was 5×5×5 mm3. The laser beam was expanded to 3 mm and split into two paths, a reference beam that passed directly through the PRC and a signal beam that was focused at the surface through a 100-X, infinity-corrected objective and returned to the PRC. The PRC matched the wave front of the reference beam to that of the signal beam for optimal interference. The interference of the two beams produced optical-intensity modulations that were correlated with surface displacements. A GHz-bandwidth photoreceiver, a low-noise 20-dB amplifier, and a 12-bit digitizer were employed for time-resolved detection of the surface-displacement signals. In combination with a 5-ns, 532-nm pump laser, the interferometric probe was employed for imaging ink patterns, such as a fingerprint, on a glass slide. The signal beam was focused at a reflective cover slip that was separated from the fingerprint by 5 mm of acoustic-coupling gel. A 3×5 mm2 area of the coverslip was raster scanned with 100-μm steps and surface-displacement signals at each location were averaged 20 times. Image reconstruction based on time reversal of the PA-induced displacement signals produced the photoacoustic image of the ink patterns. The reconstructed image of the fingerprint was consistent with its photograph, which demonstrated the ability of our system to resolve micron-scaled features at a depth of 5 mm.
Acoustic microscopy is characterized by relatively long scanning time, which is required for the motion of the transducer over the entire scanning area. This time may be reduced by using a multi-channel acoustical system which has several identical transducers arranged as an array and is mounted on a mechanical scanner so that each transducer scans only a fraction of the total area. The resulting image is formed as a combination of all acquired partial data sets. The mechanical instability of the scanner, as well as the difference in parameters of the individual transducers causes a misalignment of the image fractures. This distortion may be partially compensated for by the introduction of constant or dynamical signal leveling and data shift procedures. However, a reduction of the random instability component requires more advanced algorithms, including auto-adjustment of processing parameters. The described procedure was implemented into the prototype of an ultrasonic fingerprint reading system. The specialized cylindrical scanner provides a helical spiral lens trajectory which eliminates repeatable acceleration, reduces vibration and allows constant data flow on maximal rate. It is equipped with an array of four spherically focused 50 MHz acoustic lenses operating in pulse-echo mode. Each transducer is connected to a separate channel including pulser, receiver and digitizer. The output 3D data volume contains interlaced B-scans coming from each channel. Afterward, data processing includes pre-determined procedures of constant layer shift in order to compensate for the transducer displacement, phase shift and amplitude leveling for compensation of variation in transducer characteristics. Analysis of statistical parameters of individual scans allows adaptive eliminating of the axial misalignment and mechanical vibrations. Further 2D correlation of overlapping partial C-scans will realize an interpolative adjustment which essentially improves the output image. Implementation of this adaptive algorithm into a data processing sequence allows us to significantly reduce misreading due to hardware noise and finger motion during scanning. The system provides a high quality acoustic image of the fingerprint including different levels of information: fingerprint pattern, sweat porous locations, internal dermis structures. These additional features can effectively facilitate fingerprint based identification. The developed principles and algorithm implementations allow improved quality, stability and reliability of acoustical data obtained with the mechanical scanner, accommodating several transducers. General principles developed during this work can be applied to other configurations of advanced ultrasonic systems designed for various biomedical and NDE applications. The data processing algorithm, developed for a specific biometric task, can be adapted for the compensation of mechanical imperfections of the other devices.