Biblio
Researchers develop bioassays following rigorous experimentation in the lab that involves considerable fiscal and highly-skilled-person-hour investment. Previous work shows that a bioassay implementation can be reverse engineered by using images or video and control signals of the biochip. Hence, techniques must be devised to protect the intellectual property (IP) rights of the bioassay developer. This study is the first step in this direction and it makes the following contributions: (1) it introduces use of a sieve-valve as a security primitive to obfuscate bioassay implementations; (2) it shows how sieve-valves can be used to obscure biochip building blocks such as multiplexers and mixers; (3) it presents design rules and security metrics to design and measure obfuscated biochips. We assess the cost-security trade-offs associated with this solution and demonstrate practical sieve-valve based obfuscation on real-life biochips.
Present security study involving analysis of manipulation of individual droplets of samples and reagents by digital microfluidic biochip has remarked that the biochip design flow is vulnerable to piracy attacks, hardware Trojans attacks, overproduction, Denial-of-Service attacks, and counterfeiting. Attackers can introduce bioprotocol manipulation attacks against biochips used for medical diagnosis, biochemical analysis, and frequent diseases detection in healthcare industry. Among these attacks, hardware Trojans have created a major threatening issue in its security concern with multiple ways to crack the sensitive data or alter original functionality by doing malicious operations in biochips. In this paper, we present a systematic algorithm for the assignment of checkpoints required for error-recovery of available bioprotocols in case of hardware Trojans attacks in performing operations by biochip. Moreover, it can guide the placement and timing of checkpoints so that the result of an attack is reduced, and hence enhance the security concerns of digital microfluidic biochips. Comparative study with traditional checkpoint schemes demonstrate the superiority of the proposed algorithm without overhead of the bioprotocol completion time with higher error detection accuracy.
In this paper, we propose a new color image encryption and compression algorithm based on the DNA complementary rule and the Chinese remainder theorem, which combines the DNA complementary rule with quantum chaotic map. We use quantum chaotic map and DNA complementary rule to shuffle the color image and obtain the shuffled image, then Chinese remainder theorem from number theory is utilized to diffuse and compress the shuffled image simultaneously. The security analysis and experiment results show that the proposed encryption algorithm has large key space and good encryption result, it also can resist against common attacks.
Conventional photoacoustic microscopy (PAM) involves detection of optically induced thermo-elastic waves using ultrasound transducers. This approach requires acoustic coupling and the spatial resolution is limited by the focusing properties of the transducer. We present an all-optical PAM approach that involved detection of the photoacoustically induced surface displacements using an adaptive, two-wave mixing interferometer. The interferometer consisted of a 532-nm, CW laser and a Bismuth Silicon Oxide photorefractive crystal (PRC) that was 5×5×5 mm3. The laser beam was expanded to 3 mm and split into two paths, a reference beam that passed directly through the PRC and a signal beam that was focused at the surface through a 100-X, infinity-corrected objective and returned to the PRC. The PRC matched the wave front of the reference beam to that of the signal beam for optimal interference. The interference of the two beams produced optical-intensity modulations that were correlated with surface displacements. A GHz-bandwidth photoreceiver, a low-noise 20-dB amplifier, and a 12-bit digitizer were employed for time-resolved detection of the surface-displacement signals. In combination with a 5-ns, 532-nm pump laser, the interferometric probe was employed for imaging ink patterns, such as a fingerprint, on a glass slide. The signal beam was focused at a reflective cover slip that was separated from the fingerprint by 5 mm of acoustic-coupling gel. A 3×5 mm2 area of the coverslip was raster scanned with 100-μm steps and surface-displacement signals at each location were averaged 20 times. Image reconstruction based on time reversal of the PA-induced displacement signals produced the photoacoustic image of the ink patterns. The reconstructed image of the fingerprint was consistent with its photograph, which demonstrated the ability of our system to resolve micron-scaled features at a depth of 5 mm.