2022-06-09
Chen, Xiujuan, Liu, Jing, Lu, Tiantian, Cheng, Dengfeng, Shi, Weidong, Lei, Ting, Kang, Peng.  2021.  Operation safety analysis of CMOA controllable switch under lightning intrusion wave in UHV AC substation. 2021 International Conference on Power System Technology (POWERCON). :1452–1456.
The metal oxide arrester (MOA, shortly) is installed on the line side of the substation, which is the first line of defense for the overvoltage limitation of lightning intrusion wave. In order to deeply limit the switching overvoltage and cancel the closing resistance of the circuit breaker, the arrester is replaced by the controllable metal oxide arrester (CMOA, shortly) in the new technology. The controllable switch of CMOA can be mechanical switch or thyristor switch. Thyristor switches are sensitive to the current and current change rate (di/dt) under lightning intrusion wave. If the switch cannot withstand, appropriate protective measures must be taken to ensure the safe operation of the controllable switch under this working condition. The 1000kV West Beijing to Shijiazhuang UHV AC transmission and transformation expansion project is the first project of pilot application of CMOA. CMOA were installed at both ends of the outgoing branch of Dingtai line I. In order to study the influence of lightning intrusion wave on the controllable switch of CMOA, this paper selected this project to simulate the lightning stroke on the incoming section of Dingtai line I in Beijing West substation in the process of system air closing or single-phase reclosing, and obtained the current and di/dt of the controllable switch through CMOA under this working condition. Then the performances of mechanical and thyristor control switches were checked respectively. The results showed that the mechanical switch could withstand without protective measures. The tolerance of thyristor switch to i and di/dt exceeded the limit value, and measures should be taken to protect and limit it. In this paper, the protection measures of current limiting reactor were given, and the limiting effect of the protection measures was verified by simulation and test. It could fully meet the requirements and ensure the safe operation of thyristor controllable switch.
2020-03-16
Eneh, Joy Nnenna, Onyekachi Orah, Harris, Emeka, Aka Benneth.  2019.  Improving the Reliability and Security of Active Distribution Networks Using SCADA Systems. 2019 IEEE PES/IAS PowerAfrica. :110–115.
The traditional electricity distribution system is rapidly shifting from the passive infrastructure to a more active infrastructure, giving rise to a smart grid. In this project an active electricity distribution network and its components have been studied. A 14-node SCADA-based active distribution network model has been proposed for managing this emerging network infrastructure to ensure reliability and protection of the network The proposed model was developed using matlab /simulink software and the fuzzy logic toolbox. Surge arresters and circuit breakers were modelled and deployed in the network at different locations for protection and isolation of fault conditions. From the reliability analysis of the proposed model, the failure rate and outage hours were reduced due to better response of the system to power fluctuations and fault conditions.