Visible to the public Biblio

Filters: Keyword is Power industry  [Clear All Filters]
2023-09-07
Jin, Bo, Zhou, Zheng, Long, Fei, Xu, Huan, Chen, Shi, Xia, Fan, Wei, Xiaoyan, Zhao, Qingyao.  2022.  Software Supply Chain Security of Power Industry Based on BAS Technology. 2022 International Conference on Artificial Intelligence of Things and Crowdsensing (AIoTCs). :556–561.
The rapid improvement of computer and network technology not only promotes the improvement of productivity and facilitates people's life, but also brings new threats to production and life. Cyberspace security has attracted more and more attention. Different from traditional cyberspace security, APT attacks on key networks or infrastructure, with the main goal of stealing intellectual property, confidential information or sabotage, seriously threatening the interests and security of governments, enterprises and scientific research institutions. Timely detection and blocking is particularly important. The purpose of this paper is to study the security of software supply chain in power industry based on BAS technology. The experimental data shows that Type 1 projects account for the least amount and Type 2 projects account for the highest proportion. Type 1 projects have high unit price contracts and high profits, but the number is small and the time for signing orders is long.
2023-02-03
Zou, Zhenwan, Yin, Jun, Yang, Ling, Luo, Cheng, Fei, Jiaxuan.  2022.  Research on Nondestructive Vulnerability Detection Technology of Power Industrial Control System. 2022 IEEE 6th Information Technology and Mechatronics Engineering Conference (ITOEC). 6:1591–1594.

The power industrial control system is an important part of the national critical Information infrastructure. Its security is related to the national strategic security and has become an important target of cyber attacks. In order to solve the problem that the vulnerability detection technology of power industrial control system cannot meet the requirement of non-destructive, this paper proposes an industrial control vulnerability analysis technology combined with dynamic and static analysis technology. On this basis, an industrial control non-destructive vulnerability detection system is designed, and a simulation verification platform is built to verify the effectiveness of the industrial control non-destructive vulnerability detection system. These provide technical support for the safety protection research of the power industrial control system.

ISSN: 2693-289X

2023-01-20
Joshi, Sanskruti, Li, Ruixiao, Bhattacharjee, Shameek, Das, Sajal K., Yamana, Hayato.  2022.  Privacy-Preserving Data Falsification Detection in Smart Grids using Elliptic Curve Cryptography and Homomorphic Encryption. 2022 IEEE International Conference on Smart Computing (SMARTCOMP). :229—234.
In an advanced metering infrastructure (AMI), the electric utility collects power consumption data from smart meters to improve energy optimization and provides detailed information on power consumption to electric utility customers. However, AMI is vulnerable to data falsification attacks, which organized adversaries can launch. Such attacks can be detected by analyzing customers' fine-grained power consumption data; however, analyzing customers' private data violates the customers' privacy. Although homomorphic encryption-based schemes have been proposed to tackle the problem, the disadvantage is a long execution time. This paper proposes a new privacy-preserving data falsification detection scheme to shorten the execution time. We adopt elliptic curve cryptography (ECC) based on homomorphic encryption (HE) without revealing customer power consumption data. HE is a form of encryption that permits users to perform computations on the encrypted data without decryption. Through ECC, we can achieve light computation. Our experimental evaluation showed that our proposed scheme successfully achieved 18 times faster than the CKKS scheme, a common HE scheme.
2021-10-12
Zhang, Fengli, Huff, Philip, McClanahan, Kylie, Li, Qinghua.  2020.  A Machine Learning-Based Approach for Automated Vulnerability Remediation Analysis. 2020 IEEE Conference on Communications and Network Security (CNS). :1–9.
Security vulnerabilities in firmware/software pose an important threat ton power grid security, and thus electric utility companies should quickly decide how to remediate vulnerabilities after they are discovered. Making remediation decisions is a challenging task in the electric industry due to the many factors to consider, the balance to maintain between patching and service reliability, and the large amount of vulnerabilities to deal with. Unfortunately, remediation decisions are current manually made which take a long time. This increases security risks and incurs high cost of vulnerability management. In this paper, we propose a machine learning-based automation framework to automate remediation decision analysis for electric utilities. We apply it to an electric utility and conduct extensive experiments over two real operation datasets obtained from the utility. Results show the high effectiveness of the solution.
2021-08-11
Feng, Li, Tao, Chen, Bin, Wang, Jianye, Zhang, Song, Qing.  2020.  Research on Information Security Technology of Mobile Application in Electric Power Industry. 2020 Asia-Pacific Conference on Image Processing, Electronics and Computers (IPEC). :51—54.
With the continuous popularization of smart terminals, Android and IOS systems are the most mainstream mobile operating systems in the market, and their application types and application numbers are constantly increasing. As an open system, the security issues of Android application emerge in endlessly, such as the reverse decompilation of installation package, malicious code injection, application piracy, interface hijacking, SMS hijacking and input monitoring. These security issues will also appear on mobile applications in the power industry, which will not only result in the embezzlement of applied knowledge copyrights but also lead to serious leakage of users' information and even economic losses. It may even result in the remote malicious control of key facilities, which will cause serious social issues. Under the background of the development of smart grid information construction, also with the application and promotion of power services in mobile terminals, information security protection for mobile terminal applications and interactions with the internal system of the power grid has also become an important research direction. While analyzing the risks faced by mobile applications, this article also enumerates and analyzes the necessary measures for risk resolution.
2021-05-25
Ravikumar, Gelli, Hyder, Burhan, Govindarasu, Manimaran.  2020.  Next-Generation CPS Testbed-based Grid Exercise - Synthetic Grid, Attack, and Defense Modeling. 2020 Resilience Week (RWS). :92—98.
Quasi-Realistic cyber-physical system (QR-CPS) testbed architecture and operational environment are critical for testing and validating various cyber attack-defense algorithms for the wide-area resilient power systems. These QR-CPS testbed environments provide a realistic platform for conducting the Grid Exercise (GridEx), CPS security training, and attack-defense exercise at a broader scale for the cybersecurity of Energy Delivery Systems. The NERC has established a tabletop based GridEx platform for the North American power utilities to demonstrate how they would respond to and recover from cyber threats and incidents. The NERC-GridEx is a bi-annual activity with tabletop attack injects and incidence response management. There is a significant need to build a testbed-based hands-on GridEx for the utilities by leveraging the CPS testbeds, which imitates the pragmatic CPS grid environment. We propose a CPS testbed-based Quasi-Realistic Grid Exercise (QR-GridEx), which is a model after the NERC's tabletop GridEx. We have designed the CPS testbed-based QR-GridEx into two parts. Part-I focuses on the modeling of synthetic grid models for the utilities, including SCADA and WAMS communications, and attack-and-defense software systems; and the Part-II focuses on the incident response management and risk-based CPS grid investment strategies. This paper presents the Part-I of the CPS testbed-based QRGridEx, which includes modeling of the synthetic grid models in the real-time digital simulator, stealthy, and coordinated cyberattack vectors, and integration of intrusion/anomaly detection systems. We have used our existing HIL CPS security testbed to demonstrate the testbed-based QR-GridEx for a Texas-2000 bus US synthetic grid model and the IEEE-39 bus grid models. The experiments demonstrated significant results by 100% real-time performance with zero overruns for grid impact characteristics against stealthy and coordinated cyberattack vectors.
2021-03-22
Xu, P., Chen, L., Jiang, Y., Sun, Q., Chen, H..  2020.  Research on Sensitivity Audit Scheme of Encrypted Data in Power Business. 2020 IEEE International Conference on Energy Internet (ICEI). :6–10.

With the rapid progress of informatization construction in power business, data resource has become the basic strategic resource of the power industry and innovative element in power production. The security protection of data in power business is particularly important in the informatization construction of power business. In order to implement data security protection, transparent encryption is one of the fifteen key technical standards in the Construction Guideline of the Standard Network Data Security System. However, data storage in the encrypted state is bound to affect the security audit of data to a certain extent. Based on this problem, this paper proposes a scheme to audit the sensitivity of the power business data under the protection of encryption to achieve an efficient sensitivity audit of ciphertext data with the premise of not revealing the decryption key or data information. Through a security demonstration, this paper fully proves that this solution is secure under the known plaintext attacks.

2020-08-24
LV, Zhining, HU, Ziheng, NING, Baifeng, DING, Lifu, Yan, Gangfeng, SHI, Xiasheng.  2019.  Non-intrusive Runtime Monitoring for Power System Intelligent Terminal Based on Improved Deep Belief Networks (I-DBN). 2019 4th International Conference on Power and Renewable Energy (ICPRE). :361–365.
Power system intelligent terminal equipment is widely used in real-time monitoring, data acquisition, power management, power distribution and other tasks of smart grid. The power system intelligent terminal can obtain various information of users and power companies in the power grid, but there is still a lack of protection means for the connection and communication process of the terminal components. In this paper, a novel method based on improved deep belief network(IDBN) is proposed to accomplish the business-level security monitoring and attack detection of power system terminal. A non-intrusive business-level monitoring platform for power system terminals is established, which uses energy metering intelligent terminals as an example for non-intrusive data collection. Based on this platform, the I-DBN extracts the spatial and temporal attack characteristics of the external monitoring data of the system. Some fault conditions and cyber attacks of the model have been simulated to demonstrate the effectiveness of the proposed detection method and the results show excellent performance. The method and platform proposed in this paper can be extended to other services in the power industry, providing a theoretical basis and implementation method for realizing the security monitoring of power system intelligent terminals from the business level.
2020-03-16
Babay, Amy, Schultz, John, Tantillo, Thomas, Beckley, Samuel, Jordan, Eamon, Ruddell, Kevin, Jordan, Kevin, Amir, Yair.  2019.  Deploying Intrusion-Tolerant SCADA for the Power Grid. 2019 49th Annual IEEE/IFIP International Conference on Dependable Systems and Networks (DSN). :328–335.

While there has been considerable research on making power grid Supervisory Control and Data Acquisition (SCADA) systems resilient to attacks, the problem of transitioning these technologies into deployed SCADA systems remains largely unaddressed. We describe our experience and lessons learned in deploying an intrusion-tolerant SCADA system in two realistic environments: a red team experiment in 2017 and a power plant test deployment in 2018. These experiences resulted in technical lessons related to developing an intrusion-tolerant system with a real deployable application, preparing a system for deployment in a hostile environment, and supporting protocol assumptions in that hostile environment. We also discuss some meta-lessons regarding the cultural aspects of transitioning academic research into practice in the power industry.

2018-02-06
Vimalkumar, K., Radhika, N..  2017.  A Big Data Framework for Intrusion Detection in Smart Grids Using Apache Spark. 2017 International Conference on Advances in Computing, Communications and Informatics (ICACCI). :198–204.

Technological advancement enables the need of internet everywhere. The power industry is not an exception in the technological advancement which makes everything smarter. Smart grid is the advanced version of the traditional grid, which makes the system more efficient and self-healing. Synchrophasor is a device used in smart grids to measure the values of electric waves, voltages and current. The phasor measurement unit produces immense volume of current and voltage data that is used to monitor and control the performance of the grid. These data are huge in size and vulnerable to attacks. Intrusion Detection is a common technique for finding the intrusions in the system. In this paper, a big data framework is designed using various machine learning techniques, and intrusions are detected based on the classifications applied on the synchrophasor dataset. In this approach various machine learning techniques like deep neural networks, support vector machines, random forest, decision trees and naive bayes classifications are done for the synchrophasor dataset and the results are compared using metrics of accuracy, recall, false rate, specificity, and prediction time. Feature selection and dimensionality reduction algorithms are used to reduce the prediction time taken by the proposed approach. This paper uses apache spark as a platform which is suitable for the implementation of Intrusion Detection system in smart grids using big data analytics.

2017-03-08
Guo, Q., Fan, J., Li, N..  2015.  The achieve of power manager application honey-pot based on sandbox. 2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT). :2523–2527.

Honeypot is a common method of attack capture, can maximize the reduction of cyber-attacks. However, its limited application layer simulation makes it impossible to use effectively in power system. Through research on sandboxing technology, this article implements the simulated power manager applications by packaging real power manager applications, in order to expand the honeypot applied range.

2017-02-27
Li, X., He, Z., Zhang, S..  2015.  Robust optimization of risk for power system based on information gap decision theory. 2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT). :200–204.

Risk-control optimization has great significance for security of power system. Usually the probabilistic uncertainties of parameters are considered in the research of risk optimization of power system. However, the method of probabilistic uncertainty description will be insufficient in the case of lack of sample data. Thus non-probabilistic uncertainties of parameters should be considered, and will impose a significant influence on the results of optimization. To solve this problem, a robust optimization operation method of power system risk-control is presented in this paper, considering the non-probabilistic uncertainty of parameters based on information gap decision theory (IGDT). In the method, loads are modeled as the non-probabilistic uncertainty parameters, and the model of robust optimization operation of risk-control is presented. By solving the model, the maximum fluctuation of the pre-specified target can be obtained, and the strategy of this situation can be obtained at the same time. The proposed model is applied to the IEEE-30 system of risk-control by simulation. The results can provide the valuable information for operating department to risk management.