Biblio
The widespread diffusion of the Internet of Things (IoT) is introducing a huge number of Internet-connected devices in our daily life. Mainly, wearable devices are going to have a large impact on our lifestyle, especially in a healthcare scenario. In this framework, it is fundamental to secure exchanged information between these devices. Among other factors, it is important to take into account the link between a wearable device and a smart unit (e.g., smartphone). This connection is generally obtained via specific wireless protocols such as Bluetooth Low Energy (BLE): the main topic of this work is to analyse the security of this communication link. In this paper we expose, via an experimental campaign, a methodology to perform a vulnerability assessment (VA) on wearable devices communicating with a smartphone. In this way, we identify several security issues in a set of commercial wearable devices.
Wearables, such as Fitbit, Apple Watch, and Microsoft Band, with their rich collection of sensors, facilitate the tracking of healthcare- and wellness-related metrics. However, the assessment of the physiological metrics collected by these devices could also be useful in identifying the user of the wearable, e.g., to detect unauthorized use or to correctly associate the data to a user if wearables are shared among multiple users. Further, researchers and healthcare providers often rely on these smart wearables to monitor research subjects and patients in their natural environments over extended periods of time. Here, it is important to associate the sensed data with the corresponding user and to detect if a device is being used by an unauthorized individual, to ensure study compliance. Existing one-time authentication approaches using credentials (e.g., passwords, certificates) or trait-based biometrics (e.g., face, fingerprints, iris, voice) might fail, since such credentials can easily be shared among users. In this paper, we present a continuous and reliable wearable-user authentication mechanism using coarse-grain minute-level physical activity (step counts) and physiological data (heart rate, calorie burn, and metabolic equivalent of task). From our analysis of 421 Fitbit users from a two-year long health study, we are able to statistically distinguish nearly 100% of the subject-pairs and to identify subjects with an average accuracy of 92.97%.
Rapid advancement in wearable technology has unlocked a tremendous potential of its applications in the medical domain. Among the challenges in making the technology more useful for medical purposes is the lack of confidence in the data thus generated and communicated. Incentives have led to attacks on such systems. We propose a novel lightweight scheme to securely log the data from bodyworn sensing devices by utilizing neighboring devices as witnesses who store the fingerprints of data in Bloom filters to be later used for forensics. Medical data from each sensor is stored at various locations of the system in chronological epoch-level blocks chained together, similar to the blockchain. Besides secure logging, the scheme offers to secure other contextual information such as localization and timestamping. We prove the effectiveness of the scheme through experimental results. We define performance parameters of our scheme and quantify their cost benefit trade-offs through simulation.
Wearable Internet-of-Things (WIoT) environments have demonstrated great potential in a broad range of applications in healthcare and well-being. Security is essential for WIoT environments. Lack of security in WIoTs not only harms user privacy, but may also harm the user's safety. Though devices in the WIoT can be attacked in many ways, in this paper we focus on adversaries who mount what we call sensor-hijacking attacks, which prevent the constituent medical devices from accurately collecting and reporting the user's health state (e.g., reporting old or wrong physiological measurements). In this paper we outline some of our experiences in implementing a data-driven security solution for detecting sensor-hijacking attack on a secure wearable internet-of-things (WIoT) base station called the Amulet. Given the limited capabilities (computation, memory, battery power) of the Amulet platform, implementing such a security solution is quite challenging and presents several trade-offs with respect to detection accuracy and resources requirements. We conclude the paper with a list of insights into what capabilities constrained WIoT platforms should provide developers so as to make the inclusion of data-driven security primitives in such systems.
Wearable devices are being more popular in our daily life. Especially, smart wristbands are booming in the market recently, which can be used to monitor health status, track fitness data, or even do medical tests, etc. For this reason, smart wristbands can obtain a lot of personal data. Hence, users and manufacturers should pay more attention to the security aspects of smart wristbands. However, we have found that some Bluetooth Low Energy based smart wristbands have very weak or even no security protection mechanism, therefore, they are vulnerable to replay attacks, man-in-the-middle attacks, brute-force attacks, Denial of Service (DoS) attacks, etc. We have investigated four different popular smart wristbands and a smart watch. Among them, only the smart watch is protected by some security mechanisms while the other four smart wristbands are not protected. In our experiments, we have also figured out all the message formats of the controlling commands of these smart wristbands and developed an Android software application as a testing tool. Powered by the resolved command formats, this tool can directly control these wristbands, and any other wristbands of these four models, without using the official supporting applications.
We are witnessing a huge growth of cyber-physical systems, which are autonomous, mobile, endowed with sensing, controlled by software, and often wirelessly connected and Internet-enabled. They include factory automation systems, robotic assistants, self-driving cars, and wearable and implantable devices. Since they are increasingly often used in safety- or business-critical contexts, to mention invasive treatment or biometric authentication, there is an urgent need for modelling and verification technologies to support the design process, and hence improve the reliability and reduce production costs. This paper gives an overview of quantitative verification and synthesis techniques developed for cyber-physical systems, summarising recent achievements and future challenges in this important field.
Authentication of smartphone users is important because a lot of sensitive data is stored in the smartphone and the smartphone is also used to access various cloud data and services. However, smartphones are easily stolen or co-opted by an attacker. Beyond the initial login, it is highly desirable to re-authenticate end-users who are continuing to access security-critical services and data. Hence, this paper proposes a novel authentication system for implicit, continuous authentication of the smartphone user based on behavioral characteristics, by leveraging the sensors already ubiquitously built into smartphones. We propose novel context-based authentication models to differentiate the legitimate smartphone owner versus other users. We systematically show how to achieve high authentication accuracy with different design alternatives in sensor and feature selection, machine learning techniques, context detection and multiple devices. Our system can achieve excellent authentication performance with 98.1% accuracy with negligible system overhead and less than 2.4% battery consumption.
When clients interact with a cloud-based service, they expect certain levels of quality of service guarantees. These are expressed as security and privacy policies, interaction authorization policies, and service performance policies among others. The main security challenge in a cloud-based service environment, typically modeled using service-oriented architecture (SOA), is that it is difficult to trust all services in a service composition. In addition, the details of the services involved in an end-to-end service invocation chain are usually not exposed to the clients. The complexity of the SOA services and multi-tenancy in the cloud environment leads to a large attack surface. In this paper we propose a novel approach for end-to-end security and privacy in cloud-based service orchestrations, which uses a service activity monitor to audit activities of services in a domain. The service monitor intercepts interactions between a client and services, as well as among services, and provides a pluggable interface for different modules to analyze service interactions and make dynamic decisions based on security policies defined over the service domain. Experiments with a real-world service composition scenario demonstrate that the overhead of monitoring is acceptable for real-time operation of Web services.
Sophisticated technologies realized from applying the idea of biometric identification are increasingly applied in the entrance security management system, private document protection, and security access control. Common biometric identification involves voice, attitude, keystroke, signature, iris, face, palm or finger prints, etc. Still, there are novel identification technologies based on the individual's biometric features under development [1-4].
The aim of this study is to examine the utility of physiological compliance (PC) to understand shared experience in a multiuser technological environment involving active and passive users. Common ground is critical for effective collaboration and important for multiuser technological systems that include passive users since this kind of user typically does not have control over the technology being used. An experiment was conducted with 48 participants who worked in two-person groups in a multitask environment under varied task and technology conditions. Indicators of PC were measured from participants' cardiovascular and electrodermal activities. The relationship between these PC indicators and collaboration outcomes, such as performance and subjective perception of the system, was explored. Results indicate that PC is related to group performance after controlling for task/technology conditions. PC is also correlated with shared perceptions of trust in technology among group members. PC is a useful tool for monitoring group processes and, thus, can be valuable for the design of collaborative systems. This study has implications for understanding effective collaboration.